{"product_id":"fire-lite-mrp-2001e-six-zone-24v-deluge-preaction-control-panel-for-single-and-dual-hazard-deluge-and-preaction-applications-240v-ac","title":"Fire-Lite MRP-2001E Six-Zone 24V Deluge-Preaction Control Panel for Single and Dual Hazard Deluge and Preaction Applications, 240V AC","description":"\u003cdiv class=\"sc-bczRLJ jMeay\"\u003eThe MRP-2001 is a six-zone FACP for single and dual hazard deluge and pre-action applications. The MRP-2001 provides reliable fire detection, signaling and protection for commercial, industrial and institutional buildings requiring water-based releasing. The MRP-2001 is compatible with System Sensor's i3 detectors which are conventional smoke detectors that can transmit a maintenance trouble signal to the FACP indicating the need for cleaning and a supervisory 'freeze' signal when the ambient temperature falls below the detector rating of approximately 45°F (7.22°C).\u003c\/div\u003e\n\u003cdiv class=\"sc-bczRLJ jMeay\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"sc-bczRLJ jMeay\"\u003eIn addition, the control panel is compatible with conventional input devices such as two-wire smoke detectors, four-wire smoke detectors, pull stations, waterflow devices, tamper switches and other normally-open contact devices. Refer to the Fire-Lite Device Compatibility Document for a complete listing of compatible devices. Four outputs are programmable as NACs (Notification Appliance Circuits) or releasing circuits. Three programmable Form-C relays (factory programmed for Alarm, Trouble and Supervisory) and 24 VDC special application resettable and non-resettable power outputs are also included on the main circuit board.\u003c\/div\u003e\n\u003cdiv class=\"sc-bczRLJ jMeay\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"sc-bczRLJ jMeay\"\u003eThe MRP-2001 supervises all wiring, AC voltage, battery charger and battery level. Activation of a compatible smoke detector or any normally open fire alarm initiating device will activate audible and visual signaling devices, illuminate an indicator, display alarm information on the panel's LCD, sound the piezo sounder at the FACP, activate the FACP alarm relay and operate an optional module used to notify a remote station or initiate an auxiliary control function. The MRP-2001E offers the same features as the MRP-2001 but allows connection to 240 VAC. Unless otherwise specified, the information in this data sheet applies to both the 120 VAC and 240 VAC versions of the panels.\u003c\/div\u003e\n\u003ch3 data-test-selector=\"OverviewTitle\" class=\"TypographyStyle-sc-11lquxl gKJdoF titleText\"\u003e\u003c\/h3\u003e\n\u003ch3 data-test-selector=\"OverviewTitle\" class=\"TypographyStyle-sc-11lquxl gKJdoF titleText\"\u003eMain Features\u003c\/h3\u003e\n\u003cdiv class=\"sc-bczRLJ iKBAtS\"\u003e\n\u003cul class=\"mainfeatureslist\"\u003e\n\u003cli\u003eSix-zone FACP for deluge and pre-action applications\u003c\/li\u003e\n\u003cli\u003eCompatible with System Sensor's i3 detectors\u003c\/li\u003e\n\u003cli\u003eSupports conventional input devices\u003c\/li\u003e\n\u003cli\u003eProgrammable NACs and releasing circuits\u003c\/li\u003e\n\u003cli\u003eIncludes 24 VDC resettable power outputs\u003c\/li\u003e\n\u003cli\u003eSupervises wiring, AC voltage, and battery level\u003c\/li\u003e\n\u003cli\u003eActivates audible and visual signaling devices\u003c\/li\u003e\n\u003cli\u003e240V AC connection for MRP-2001E version\u003c\/li\u003e\n\u003cli\u003ecompatible with: \u003ca rel=\"noopener\" href=\"https:\/\/www.fireandsafetyplus.com\/product\/firelite-cac-5x-class-a-converter-module\/\" target=\"_blank\"\u003eCAC-5X\u003c\/a\u003e, \u003ca rel=\"noopener\" href=\"https:\/\/www.fireandsafetyplus.com\/product\/firelite-4xtmf-remote-station-output-or-municipal-box-connection-24vdc\/\" target=\"_blank\"\u003e4XTMF \u003c\/a\u003e, \u003ca rel=\"noopener\" href=\"https:\/\/www.fireandsafetyplus.com\/product\/fire-lite-ann-sec-secondary-annunciator-bus-port\/\" target=\"_blank\"\u003eANN-SEC ,\u003c\/a\u003e \u003ca rel=\"noopener\" href=\"https:\/\/www.fireandsafetyplus.com\/product\/fire-lite-ann-80-lcd-annunciator\/\" target=\"_blank\"\u003eANN-80 LCD\u003c\/a\u003e, \u003ca rel=\"noopener\" href=\"https:\/\/www.fireandsafetyplus.com\/product\/fire-lite-ann-led-annunciator-module\/\" target=\"_blank\"\u003eANN-LED\u003c\/a\u003e, \u003ca rel=\"noopener\" href=\"https:\/\/www.fireandsafetyplus.com\/product\/fire-lite-ann-rly-relay-board\/\" target=\"_blank\"\u003eANN-RLY\u003c\/a\u003e, \u003ca rel=\"noopener\" href=\"https:\/\/www.fireandsafetyplus.com\/product\/fire-lite-ann-s-pg-serial-printer-interface-module\/\" target=\"_blank\"\u003eANN-S\/PG \u003c\/a\u003e, \u003ca rel=\"noopener\" href=\"https:\/\/www.fireandsafetyplus.com\/product\/fire-lite-ann-i-o-led-driver-module\/\" target=\"_blank\"\u003eANN-I\/O\u003c\/a\u003e, \u003ca rel=\"noopener\" href=\"https:\/\/www.fireandsafetyplus.com\/product\/fire-lite-dp-51050-dress-panel\/\" target=\"_blank\"\u003eDP-51050\u003c\/a\u003e, \u003ca rel=\"noopener\" href=\"https:\/\/www.fireandsafetyplus.com\/product\/trce-fire-lite-trim-ring-control-panel\/\" target=\"_blank\"\u003eTR-CE \u003c\/a\u003e, \u003ca rel=\"noopener\" href=\"https:\/\/www.fireandsafetyplus.com\/product\/fire-lite-bb-55f-battery-cabinet-backbox\/\" target=\"_blank\"\u003eBB-55F\u003c\/a\u003e, \u003ca rel=\"noopener\" href=\"https:\/\/www.fireandsafetyplus.com\/product\/fire-lite-battery-charger\/\" target=\"_blank\"\u003eCHG-120F\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Fire-lite Alarms By Honeywell","offers":[{"title":"Default Title","offer_id":43246882816065,"sku":"FL-MRP2001E","price":1332.66,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0700\/2465\/9009\/files\/f713420d-1060132349_lg.jpg?v=1770764679","url":"https:\/\/www.fireandsafetyplus.com\/products\/fire-lite-mrp-2001e-six-zone-24v-deluge-preaction-control-panel-for-single-and-dual-hazard-deluge-and-preaction-applications-240v-ac","provider":"Fire and Safety Plus","version":"1.0","type":"link"}